OT-2 Python API Version 1

The Opentrons API is a simple Python framework designed to make writing automated biology lab protocols easy.

We’ve designed it in a way we hope is accessible to anyone with basic Python and wetlab skills. As a bench scientist, you should be able to code your automated protocols in a way that reads like a lab notebook.


Getting Started

New to Python? Check out our Using Python In Protocols page first before continuing. To get a sense of the typical structure of our scripts, take a look at our Examples page.

Our API requires Python version 3.7.6 or later. Once this is set up on your computer, you can simply use pip to install the Opentrons package.

pip install opentrons

To simulate protocols on your laptop, check out Simulating Your Scripts. When you’re ready to run your script on a robot, download our latest desktop app

Troubleshooting

If you encounter problems using our products please take a look at our support docs or contact our team via intercom on our website at opentrons.com.


Overview

How it Looks

The design goal of the Opentrons API is to make code readable and easy to understand. For example, below is a short set of instruction to transfer from well 'A1' to well 'B1' that even a computer could understand:

Use the Opentrons API's labware and instruments

This protocol is by me; it’s called Opentrons Protocol Tutorial and is used for demonstrating the Opentrons API

Add a 96 well plate, and place it in slot '2' of the robot deck
Add a 200uL tip rack, and place it in slot '1' of the robot deck

Add a single-channel 300uL pipette to the left mount, and tell it to use that tip rack

Transfer 100uL from the plate's 'A1' well to it's 'B2' well

If we were to rewrite this with the Opentrons API, it would look like the following:

# imports
from opentrons import labware, instruments

# metadata
metadata = {
    'protocolName': 'My Protocol',
    'author': 'Name <email@address.com>',
    'description': 'Simple protocol to get started using OT2',
}

# labware
plate = labware.load('96-flat', '2')
tiprack = labware.load('opentrons_96_tiprack_300ul', '1')

# pipettes
pipette = instruments.P300_Single(mount='left', tip_racks=[tiprack])

# commands
pipette.transfer(100, plate.wells('A1'), plate.wells('B2'))

How it’s Organized

When writing protocols using the Opentrons API, there are generally five sections:

  1. Imports

  2. Metadata

  3. Labware

  4. Pipettes

  5. Commands

Imports

When writing in Python, you must always include the Opentrons API within your file. We most commonly use the labware and instruments sections of the API.

From the example above, the “imports” section looked like:

from opentrons import labware, instruments

Metadata

Metadata is a dictionary of data that is read by the server and returned to client applications (such as the Opentrons App). It is not needed to run a protocol (and is entirely optional), but if present can help the client application display additional data about the protocol currently being executed.

The fields above (“protocolName”, “author”, and “description”) are the recommended fields, but the metadata dictionary can contain fewer or additional fields as desired (though non-standard fields may not be rendered by the client, depending on how it is designed).

You may see a metadata field called “source” in protocols you download directly from Opentrons. The “source” field is used for anonymously tracking protocol usage if you opt-in to analytics in the Opentrons App. For example, protocols from the Opentrons Protocol Library may have “source” set to “Opentrons Protocol Library”. You shouldn’t define “source” in your own protocols.

Labware

While the imports section is usually the same across protocols, the labware section is different depending on the tip racks, well plates, troughs, or tubes you’re using on the robot.

Each labware is given a type (ex: '96-flat'), and the slot on the robot it will be placed (ex: '2').

From the example above, the “labware” section looked like:

plate = labware.load('96-flat', '2')
tiprack = labware.load('opentrons_96_tiprack_300ul', '1')

Pipettes

Next, pipettes are created and attached to a specific mount on the OT-2 ('left' or 'right').

There are other parameters for pipettes, but the most important are the tip rack(s) it will use during the protocol.

From the example above, the “pipettes” section looked like:

pipette = instruments.P300_Single(mount='left', tip_racks=[tiprack])

Commands

And finally, the most fun section, the actual protocol commands! The most common commands are transfer(), aspirate(), dispense(), pick_up_tip(), drop_tip(), and much more.

This section can tend to get long, relative to the complexity of your protocol. However, with a better understanding of Python you can learn to compress and simplify even the most complex-seeming protocols.

From the example above, the “commands” section looked like:

pipette.transfer(100, plate.wells('A1'), plate.wells('B1'))

Feature Requests

Have an interesting idea or improvement for our software? Create a ticket on github by following these guidelines.

Developer’s guide

Do you want to contribute to our open-source API? You can find more information on how to be involved here.