Magnetic Block

MagneticBlockContext

An object representing a Magnetic Block.

It should not be instantiated directly; instead, it should be created through ProtocolContext.load_module().

New in version 2.15

labware property v2.0

labware: Labware | None

The labware (if any) present on this module.

load_adapter v2.15

load_adapter(
    name: str, namespace: str | None = None, version: int | None = None
) -> Labware

Load an adapter onto the module using its load parameters.

The parameters of this function behave like those of load_adapter() (which loads adapters directly onto the deck). Note that the parameter name here corresponds to load_name on the ProtocolContext function.

Returns:

  • Labware –

    The initialized and loaded adapter object.

load_adapter_from_definition v2.15

load_adapter_from_definition(definition: LabwareDefinition) -> Labware

Load an adapter onto the module using an inline definition.

Parameters:

  • definition (LabwareDefinition) –

    The labware definition.

Returns:

  • Labware –

    The initialized and loaded labware object.

load_labware

load_labware(
    name: str,
    label: str | None = None,
    namespace: str | None = None,
    version: int | None = None,
    adapter: str | None = None,
    lid: str | None = None,
    *,
    adapter_namespace: str | None = None,
    adapter_version: int | None = None,
    lid_namespace: str | None = None,
    lid_version: int | None = None
) -> Labware

Load a labware onto the module using its load parameters.

The parameters of this function behave like those of load_labware() (which loads labware directly onto the deck). Note that the parameter name here corresponds to load_name on the ProtocolContext function.

Returns:

  • Labware –

    The initialized and loaded labware object.

New in version 2.1: The label, namespace, and version parameters.

New in version 2.26: The adapter_namespace, adapter_version, lid_namespace, and lid_version parameters.

load_labware_by_name v2.1

load_labware_by_name(
    name: str,
    label: str | None = None,
    namespace: str | None = None,
    version: int | None = None,
) -> Labware

Deprecated in version 2.0: Use load_labware instead.

load_labware_from_definition v2.0

load_labware_from_definition(
    definition: LabwareDefinition, label: str | None = None
) -> Labware

Load a labware onto the module using an inline definition.

Parameters:

  • definition (LabwareDefinition) –

    The labware definition.

  • label (str, default: None ) –

    An optional special name to give the labware. If specified, this is the name the labware will appear as in the run log and the calibration view in the Opentrons App.

Returns:

  • Labware –

    The initialized and loaded labware object.

model property v2.14

model: ModuleModel

Get the module's model identifier.

parent property v2.14

parent: str

The name of the slot the module is on.

On a Flex, this will be like "D1". On an OT-2, this will be like "1". See Deck Slots.

type property v2.14

type: ModuleType

Get the module's general type identifier.